Type of Indoor Unit | Product | 6 | 7 | 9 | 12 | 14 | 15 | 18 | 22 | 24 | 30 | 36 | 42 | 48 | 54 | 72 | 96 | 192 |
● | ● | ● | ● | ● | ● | ● | ● | |||||||||||
● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |||||
● | ● | ● | ● | |||||||||||||||
● | ● | ● | ● | ● | ● | ● | ||||||||||||
● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |||||||||
● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ||||||||
● | ● | ● | ● | ● | ||||||||||||||
● | ● | ● | ● | ● | ||||||||||||||
● | ● | ● | ||||||||||||||||
● | ● | ● | ● | ● | ● | ● | ● | ● | ||||||||||
● | ● | ● | ● | ● | ||||||||||||||
● | ● | ● | ● | ● | ● | ● | ● | |||||||||||
● | ● | ● | ● | ● | ● | ● | ● | ● | ||||||||||
● | ● | ● | ● | ● | ||||||||||||||
● | ● | ● | ● | ● |
High Static Pressure Duct Unit
High static pressure design
- Static pressure can be up to 200Pa(0.8In.W.G), especially suitable for places in need of long distance airflow.
Easy maintenance
- The system has maintenance port for easy maintenance.
Convenient installation
- You can choose circular air duct or rectangular air duct according to actual needs. Or you can choose different ways of air return.
Protection function
- Anti-freezing protection, fan motor overload protection, temperature sensor malfunction protection.
Super High Static Pressure Duct Unit
High static pressure design
- Static pressure can be up to 275Pa(1.1In.W.G), especially suitable for places in need of long distance airflow.
Easy maintenance
- The system has maintenance port for easy maintenance.
Convenient installation
- You can choose circular air duct or rectangular air duct according to actual needs. Or you can choose different ways of air return.
Protection function
- Anti-freezing protection, fan motor overload protection, temperature sensor malfunction protection.
Medium Static Pressure Duct Unit
Medium static pressure design with multiple static pressure levels for your option
- External static pressure design reaches 80Pa (0.3In.W.G) for multiple air supply areas and long air supply distance, satisfying various layout requirements. With five external static pressure levels, convenient for engineering design and application.
DC motor design with energy-saving and quiet operation
- DC brushless motor is adopted to achieve stepless adjustment of rotation speed, more stable speed adjustment and quieter operation.
Intelligent drain device without height limitation
- DC drain pump is equipped with maximum lift height of 1m, solving the condensate drainage problem caused by small installation space and saving the installation space.
Multiple protections function
- Water-full protection, freeze prevention, abnormal temperature sensor protection and built-in fan overload protection, etc.
Low Static Pressure Duct Unit
Low static pressure, low noise
- Especially suitable for rooms of compact structure or small installation space. Also, it provides you with a comfortable and quiet living environment.
Intelligent drainage device
- Water height difference up to 1.2m(3-15/16ft.), which can effectively drain out condensing water and save space
Convenient installation
- Tab type plastic filter, detachable fan motor, independent water pump assembly and electric box assembly, all for convenient maintenance.
Protections function
- Water overflow protection, anti-freezing protection, fan motor overload protection, temperature sensor malfunction protection.
4-Way Cassette Unit
Strong and balanced airflow
- Unit features auto operation, 4-way airflow, 7 fan speeds and strong circulating airflow.
Ultra-low noise operation
- DC inverter motor can realize stepless speed regulation to lower noise. Indoor unit can be set to work under auto quiet mode via wired controller.
Intelligent drainage device
- Water height difference up to 1.2m(3-15/16ft.), which can effectively drain out condensing water and save space.
DC inverter motor
- With good speed regulation performance, motor efficiency improved by 30% v.s. normal motor.
Protections function
- Water overflow protection, anti-freezing protection, fan motor overload protection, temperature sensor malfunction protection.
360° Air Discharge Cassette Indoor Unit
360°Air Supply
- 360 ° air supply design to make indoor air flow more even and temperature distribution more comfortable to avoid any blind angle.
Individual Swing Control
- Individual swing control of four air guide louvers to set fixed supply air or swing supply air in different angles individually, satisfying the user’ s individualized requirements on temperature and air flow distribution in different indoor locations, thus enhancing comfort.
Lifting Water Pump of Condensate
- With direct current drainage pump, the operation noise is lower and the lift reaches 1,200mm.
Fresh Air Function
- With the healthy fresh air accessories, it can bring in 8%~10% of fresh outdoor air effectively, improving air quality of indoor unit.
I-feel Technology (Custom-made)
- The advanced I-feel technology can detect human indoor activities at real time and realize intelligent control to the operation status of the indoor unit, thus reaching a higher energy conservation level.
Fresh Air Ventilation Kit
Fresh air quality
- The fresh air device operates by matching with 4-way cassette indoor unit, supplying indoor side with outdoor fresh air to improve indoor air quality and then let users enjoy the fresher air.
Beautiful Appearance
- With beautiful and elegant outlook, can be used matched with 4-way cassette.
Compact 4-Way Cassette Unit
Compact Design for Easy Installation
- Units maintain the uniform length and width with consistent ceiling opening and panel dimension, convenient for design and installation.
Intelligent drainage device
- Water height difference up to 1.2m(3-15/16ft.), which can effectively drain out condensing water and save space.
Ultra-low noise operation
- DC inverter motor can realize stepless speed regulation to lower noise. Indoor unit can be set to work under auto quiet mode via wired controller.
2-Way Cassette Unit
Beautiful Appearance
- With beautiful and elegant front panel, it is congenial to the indoor surroundings.
Two-way air flow design
- Two-way air outlet, to stretch air outlet distance and solve air supply problem of elongated room.
Intelligent drainage device
- Water height difference up to 1.2m(3-15/16ft.), which can effectively drain out condensing water and save space.
Multiple protections
- Anti-freezing protection, temperature malfunction protection, fan motor overload and humidity sensor protection.
1-Way Cassette Indoor Unit
Small installation space
- With 185mm(7-1/4 in.) ultrathin design, unit can be installed in the ceiling of 19cm deep.
High drain pump lift
- Drain pump lift reaches 1.2m(3-15/16ft.), which can effectively drain out water.
Detachable grille and long life filter
- Grille is detachable for easy cleaning. With durable filter, cleaning cycle is 20 times longer.
Protection function
- Water overflow protection, anti-freezing protection, fan motor overload protection, temperature sensor malfunction protection.
Wall-mounted Type
Comfortable and balanced airflow, up&down air outlet
- Up air outlet: In cooling, cool air blows out horizontally and then gradually drops.
- Down air swing: In heating, warm air blows downward and then gradually climbs up.
Cold air prevention design
- During heating in winter, cold air prevention function is enabled so that air won’t be blown out.
until it’s warm
Detachable grille and long life filter
- Grille is detachable for easy cleaning. With durable filter, cleaning cycle is 20 times longer.
Triple defenders for better purification
- Mildew-proof filter, electrostatic fibre and anti-biotic fibre adopted to remove dust, smell, bacteria and mildew.
Multiple protections
- Anti-freezing protection, temperature sensor malfunction protection, fan motor overload protection.
Console
Multiple fan speed
- The fan can operate in multiple speed and satisfy different air flow volume requirements.
Detachable grille and long life filter
- Grille is detachable for easy cleaning. With long life filter, cleaning cycle is 20 times longer.
Protection function
- Anti-freezing protection, fan motor overload protection, temperature sensor malfunction protection.
Floor Ceiling Type
Hoisted or seated, flexible installation
- Unit can be hoisted or seated. When seated, suspended ceiling is not needed.
Horizontal and vertical air swing
- Wider air swing range for your comfortable working and living environment.
Protection function
- Anti-freezing protection, fan motor overload protection, temperature sensor malfunction protection.
Protection function
- Anti-freezing protection, fan motor overload protection, temperature sensor malfunction protection.
Flash Air Processing Unit
One system, Two functions
Adopted with DC inverter technology, Fresh Air DC Inverter Multi VRF System features air conditioning function and fresh air function.
Enjoy Fresh Air
- Airflow volume: 589~2060CFM, cooling capacity: 42~96 kBtu/h.
- Applicable for all kinds of structure.
- Direct evaporative cooling adopted , air conditioning+fresh air can be realized accurately and precisely.
- DC inverter technology adopted , constant humidity is enabled with less power consumption.
- Integrated system control with Gree GMV Multi VRF System.
Less investment
- Fresh Air DC Inverter Multi VRF System can be combined with Gree GMV5. For a same room, if the same amount of fresh air is to be taken, then the cost of MV5+Fresh air unit is equivalent to the cost of GMV+Air exchange fan.
Less operation cost
- Unit can control refrigerant output according to actual needs to ensure constant airflow temperature. By adjusting power output, light-load but high power operation can be avoided. Thus, operation cost can be greatly reduced.
AHU KIT
- With functions and advantages of VRF unit.
- Multiple installation methods, convenient for project design.
- Independent design, convenient for installation.
- With wide capacity range.
- Error signal connected, safe and reliable for operation.
- Take the outdoor unit of VRF unit as the cold and heat
sources, no need extra cold and heat sources. - Dual control methods: general indoor unit control or fresh
function control for selection.
Air Handler
Highly Flexible Installation
- The unit is designed for outdoor installation and less indoor space taking, allowing easy installation and maintenance. The unit can be installed on the ground or on the roof of the building, which means the installation is totally flexible depending on the project requirement.
Cold Air Prevention Design
- When heating in winter, cold air prevention function is enabled so that air won’t be blown out until it’s warm.
Long life and Washable Filter
- The filter is easy to be dismantled and installed. You can use dust collector or water to clear away the dust.